Free ground shipping on U.S. orders over $399 within the 48 contiguous states

HEAT ROLL™

flexible heat where and when you need it

Free shipping (2-3 business days)

60-day return policy

15 year warranty

Starting from $49

Get a $49 rebate off your purchase when switching a baseboard heater!*

*offer applies to max. three (3) baseboard heaters for areas over 50 sq. ft. 

HEAT ROLL™

flexible heat where and when you need it

Free shipping (2-3 business days)

60-day return policy

15 year warranty

Starting from $49

Get a $49 rebate off your purchase when switching a baseboard heater!*

*offer applies to max. three (3) baseboard heaters for areas over 50 sq. ft. 

PRINTED ELECTRIC HEATING

the LED to Heating

Sheet-type electric heating resistors, printed using carbon inks, that improve heat distribution by up to 35% compared to existing electric solutions.

HEAT ROLL™ is terminated with connectors and wiring (sold separately).

PRINTED ELECTRIC HEATING

the LED to Heating

Sheet-type electric heating resistors, printed using carbon inks, that improve heat distribution by up to 35% compared to existing electric solutions.

HEAT ROLL™ is terminated with connectors and wiring (sold separately).

INSTALLATION

Get ready to roll

with HEAT ROLL™ 

Improve comfort and save on energy with electric radiant heating installed under laminate, engineered wood, tile, vinyl and carpet over existing floors or wood and concrete subfloors.

HEAT ROLL™ is installed with electrical grounding and underlayments or backer board at least 3/16 in. thick (sold separately).

WOOD SUBFLOOR
Min. 0.5 in. | R-19

Constructed with MDF, or existing wood floor, with 2 in. air gap and R-19 insulation or higher.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
VAPOR BARRIER MEMBRANE
Min. 0.004 in.

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
LAMINATE FLOOR COVERING
Max. 0.500 in. | R-0.5

Floating over vapor barrier or similar membrane, and includes engineered wood or other floating floor covering (no nail-down).

LAMINATE FLOOR (Floating)
Over Wood/Concrete Subfloor

WOOD SUBFLOOR
Min. 0.5 in. | R-19

Constructed with MDF, or existing wood floor, with 2 in. air gap and R-19 insulation or higher.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
WATERPROOFING MEMBRANE
Min. 0.004 in., Max. R-0.1

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
THINSET MORTAR
Max. 0.125 in., R-0.050

Unmodified or modified concrete mortar mix overtop waterproofing membrane.
TILE FLOOR COVERING
Max. 0.500 in. | R-0.4

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).

TILE & STONE FLOOR (Fixed)
Over Wood Subfloor

CONCRETE SUBFLOOR
Min. 3.5 in. | R-6

Existing concrete subfloor, or with additional backer board, subfloor panel, or cork insulation for easy cable routing (Min. 0.20 in.).
WATERPROOFING ADHESIVE
Min. 0.010 in. | R-0.05

Rolled over existing concrete subfloor or backer board.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in.

Heater element with grounding sheath (RG-Series not shown), without thermal underlayment.
WATERPROOFING MEMBRANE
Min. 0.004 in., Max. R-0.1

Uncoupling, crack isolation, or anti-fracture membrane with perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
THINSET MORTAR
Max. 0.125 in., R-0.050

Unmodified or modified concrete mortar mix overtop waterproofing membrane.
TILE FLOOR COVERING
Max. 0.500 in. | R-0.4

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).

TILE & STONE FLOOR (Fixed)
Over Concrete Subfloor

WOOD OR CONCRETE SUBFLOOR
Min. 3.5 in. | R-6

Existing floor, wood or concrete subfloor, with or without additional backer board, subfloor panel, or cork insulation.
VINYL & CARPET COVERING
Max. 0.125 in. | R-0.8

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
VAPOR BARRIER MEMBRANE
Min. 0.004 in.

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
MDF SHEETS
Max. 0.5 in., R-0.5

MDF or wood sheets placed overtop vapor barrier membrane before installing floor coverings with adhesive or stapled (Max. 0.4375 in.).
VINYL & CARPET FLOOR COVERING
Max. 0.125 in. | R-0.8

Fixed (stapled) or floating over wood sheets, and includes sheet vinyl, vinyl tiles, linoleum tiles, low-pile carpets, and carpet squares.

VINYL & CARPET FLOOR (Fixed)
Over Wood/Concrete Subfloor

INSTALLATION

Get ready to roll with HEAT ROLL™ 

Improve comfort and save on energy with electric radiant heating installed under laminate, engineered wood, tile, vinyl and carpet over existing floors or wood and concrete subfloors.

HEAT ROLL™ is installed with electrical grounding and underlayments or backer board at least 3/16 in. thick (sold separately).

WOOD SUBFLOOR
Min. 0.5 in. | R-19

Constructed with MDF, or existing wood floor, with 2 in. air gap and R-19 insulation or higher.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
VAPOR BARRIER MEMBRANE
Min. 0.004 in.

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
LAMINATE FLOOR COVERING
Max. 0.500 in. | R-0.5

Floating over vapor barrier or similar membrane, and includes engineered wood or other floating floor covering (no nail-down).

LAMINATE FLOOR (Floating)
Over Wood/Concrete Subfloor

WOOD SUBFLOOR
Min. 0.5 in. | R-19

Constructed with MDF, or existing wood floor, with 2 in. air gap and R-19 insulation or higher.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
WATERPROOFING MEMBRANE
Min. 0.004 in., Max. R-0.1

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
THINSET MORTAR
Max. 0.125 in., R-0.050

Unmodified or modified concrete mortar mix overtop waterproofing membrane.
TILE FLOOR COVERING
Max. 0.500 in. | R-0.4

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).

TILE & STONE FLOOR (Fixed)
Over Wood Subfloor

CONCRETE SUBFLOOR
Min. 3.5 in. | R-6

Existing concrete subfloor, or with additional backer board, subfloor panel, or cork insulation for easy cable routing (Min. 0.20 in.).
WATERPROOFING ADHESIVE
Min. 0.010 in. | R-0.05

Rolled over existing concrete subfloor or backer board.
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in.

Heater element with grounding sheath (RG-Series not shown), without thermal underlayment.
WATERPROOFING MEMBRANE
Min. 0.004 in., Max. R-0.1

Uncoupling, crack isolation, or anti-fracture membrane with perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
THINSET MORTAR
Max. 0.125 in., R-0.050

Unmodified or modified concrete mortar mix overtop waterproofing membrane.
TILE FLOOR COVERING
Max. 0.500 in. | R-0.4

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).

TILE & STONE FLOOR (Fixed)
Over Concrete Subfloor

WOOD OR CONCRETE SUBFLOOR
Min. 3.5 in. | R-6

Existing floor, wood or concrete subfloor, with or without additional backer board, subfloor panel, or cork insulation.
VINYL & CARPET COVERING
Max. 0.125 in. | R-0.8

Fixed over thinset mortar, and includes marble, stone, or other fixed floor covering (no nail-down).
HEAT ROLL™ R/RG-SERIES
Min. 0.200 in. | R-1.5

Heater element with grounding sheath (RG-Series not shown) and thermal underlayment (Min. 0.1875 in.).
VAPOR BARRIER MEMBRANE
Min. 0.004 in.

Perm rating of 0.1 or less, over entire installation with 6 in. sealed overlap.
MDF SHEETS
Max. 0.5 in., R-0.5

MDF or wood sheets placed overtop vapor barrier membrane before installing floor coverings with adhesive or stapled (Max. 0.4375 in.).
VINYL & CARPET FLOOR COVERING
Max. 0.125 in. | R-0.8

Fixed (stapled) or floating over wood sheets, and includes sheet vinyl, vinyl tiles, linoleum tiles, low-pile carpets, and carpet squares.

VINYL & CARPET FLOOR (Fixed)
Over Wood/Concrete Subfloor

SPECS & FEATURES

Get to know

your HEAT ROLL™

Electric heating resistors designed for any DC or AC voltage with a current rating up to 15A. For large surface areas, 120 VAC or 220 – 240 VAC, is most practical with coverage up to 180 sq. ft. depending on the power density and ground protection.

HEAT ROLL™ is available pre-laminated with electrical grounding and underlayments (orders over 2,500 sq. ft.).

VIEW DETAILED SPECS
Electrical
Voltage: 120 VAC & 220 – 240 VAC
Current: Max. 15 A
Power: 7 – 22 Watts per sq. ft.
Temperature
Max. Operating Temp.: 50°C (122°F)
Insulation Temp. Class: 105°C (221°F)
Dimensions
Thickness: 0.013 in. – 0.200 in.
Max. Width: 39 in.
Max. Length: 492 ft.
Storage
-35° to 45°C
5% to 95% RH (non condensing)
Certifications
UL 499
CSA C22.2 No. 72
Flexible

Available in different widths and can be rolled onto any surface.

Cut-to-length

Use a pair of scissors to adjust heaters to any length.

Parallel
Circuit design prevents electrical shorts and zone loss, making it more reliable.
Efficient

SPECS & FEATURES

Get to know your HEAT ROLL™

Electric heating resistors designed for any DC or AC voltage with a current rating up to 15A. For large surface areas, 120 VAC or 220 – 240 VAC, is most practical with coverage up to 180 sq. ft. depending on the power density and ground protection.

HEAT ROLL™ is available pre-laminated with electrical grounding and underlayments (orders over 2,500 sq. ft.).

VIEW DETAILED SPECS
Electrical Voltage: 120 VAC & 220 – 240 VAC
Current: Max. 15 A
Power: 7 – 22 Watts per sq. ft.
Temperature Max. Operating Temp.: 50°C (221°F)
Insulation Temp. Class: 105°C (122°F)
Dimensions Thickness: 0.013 in. – 0.200 in.
Max. Width: 39 in.
Max Length: 492 ft.
Storage -35° to 45°C
5% to 95% RH (non condensing)
Certifications UL 499
CSA C22.2 No. 72
Flexible

Available in different widths and can be rolled onto any surface.

Cut-to-length

Use a pair of scissors to adjust heaters to any length.

Parallel
Circuit design prevents electrical shorts and zone loss, making it more reliable.
Efficient

Why Radiant Heating?

Electrical resistance generates heat that is then radiated to the solid objects in a room. With radiant heating, solid objects retain their energy longer than hot air generated by furnaces or baseboard heaters. The operating cost for your radiant heating system will depend on a few things like the size of your system, the temperature you’re trying to achieve, and the cost of electricity in your area.

 

Cost Calculator

Please exclude area occupied by permanent fixtures.
6
Operating Cost ($/day)

Why Radiant Heating?

Electrical resistance generates heat that is then radiated to the solid objects in a room. With radiant heating, solid objects retain their energy longer than hot air generated by furnaces or baseboard heaters. The operating cost for your radiant heating system will depend on a few things like the size of your system, the temperature you’re trying to achieve, and the cost of electricity in your area.

 

Cost Calculator

Please exclude area occupied by permanent fixtures.
6
Operating Cost ($/day)

RESIDENTIAL HEATING

The one heat source you
can’t wait to turn on

Transfer heat efficiently to surfaces

Precisely heat where & when you need it

Save money, energy & the environment

CoMMERCIAL HEATING

The smart solution for your next project 

Save on installation cost & turn-around

Improve energy savings & performance

Reduce maintenance costs & repairs

RESIDENTIAL HEATING 

The one heat source you
can’t wait to turn on

We know how uncomfortable cold areas can be at home,
so treat yourself to gentle radiant heat with HEAT ROLL™.

Transfer heat efficiently to surfaces

Distribute heat where & when you need it

Save money, energy & the environment

COMMERCIAL HEATING

The smart solution
for your next project

Better manage energy expenses while keeping occupants comfortable by heating areas as needed with HEAT ROLL™.

Save on installation cost & turn-around

Improve energy savings & performance

Reduce maintenance costs & repairs

EASY SETUP

It’s simple to get rolling

Will it work with my application?

Make sure your HEAT ROLL™ is compatible with your electrical wiring and distribution panel.

Can I install it myself?

Yes, you can assemble HEAT ROLL™ yourself, but a licensed electrician must connect it to power.

Can I get it professionally installed?

Yes, a flooring professional may assemble HEAT ROLL™ before an electrician inspects and connects it.

NOT THE DIY TYPE?

Hire a local contractor carefully selected to install it for you

EASY SETUP

It’s simple to get rolling

Will it work with my application?

Make sure your HEAT ROLL™ is compatible with your electrical wiring and distribution panel.

Check Compatibility >

Can I install it myself?

Yes, you can assemble HEAT ROLL™ yourself, but a licensed electrician must connect it to power.

Can I get it professionally installed?

Yes, a flooring professional may assemble HEAT ROLL™ before an electrician inspects and connects it.

NOT THE DIY TYPE?

Hire a local contractor carefully selected to install it for you

HEAT ROLL™

flexible heat where and when you need it

Starting from $49

Get a $49 rebate off your purchase when switching a baseboard heater!*

*offer applies to max. three (3) baseboard heaters for areas over 50 sq. ft.  

Free shipping (2-3 business days)

60-day return policy

15 year warranty

UL/CSA certified heater element

POWER ROLL™
Assembly Kit

Save when you buy them together.

Starting from $184

Smart Thermostat
& Sensor

Save when you buy them together.

$169

HEAT ROLL™

flexible heat where and when you need it

Starting from $49

Get a $49 rebate off your purchase when switching a baseboard heater!*

*offer applies to max. three (3) baseboard heaters for areas over 50 sq. ft. 

Free shipping (2-3 business days)

60-day return policy

15 year warranty

UL/CSA certified heater element

POWER ROLL™
Assembly Kit

Save when you buy them together.

Starting from $184

Smart Thermostat
& Sensor

Save when you buy them together.

$169